Delivery: Neutralization assay report
QC standard: S/N ≥ 100
Turnaround time: 1-3 weeks*
*TAT may extend due to the number of samples.Product | Cat. No. | name | Deliverable | TAT |
---|---|---|---|---|
Luciferase reporter kit | SC2087A | SARS-CoV-2 Pseudovirus Neutralization Assay kit_Luc reporter |
Components: |
Wild type:4 weeks Mutant type:Quote |
SC2087B | SARS-CoV-2 D614G Pseudovirus Neutralization Assay kit_Luc reporter | |||
SC2087C | SARS-CoV-2 V367F Pseudovirus Neutralization Assay kit _Luc reporter | |||
SC2087D | SARS-CoV-2 W436R Pseudovirus Neutralization Assay kit _Luc reporter | |||
SC2087E | SARS-CoV-2 D364Y Pseudovirus Neutralization Assay kit _Luc reporter | |||
SC2087K | SARS-CoV-2 N501Y (B.1.1.7) Pseudovirus Neutralization Assay kit _Luc reporter | |||
SC2087L | SARS-CoV-2 N501Y (B.1.351) Pseudovirus Neutralization Assay kit _Luc reporter | |||
SC2087M | SARS-CoV-2 A222V Pseudovirus Neutralization Assay kit _Luc reporter | |||
SC2087N | SARS-CoV-2 N439K Pseudovirus Neutralization Assay kit _Luc reporter | |||
SC2087O | SARS-CoV-2 S477N Pseudovirus Neutralization Assay kit _Luc reporter | |||
SC2087P | SARS-CoV-2 E484K Pseudovirus Neutralization Assay kit _Luc reporter | |||
SC2087Q | SARS-CoV-2 Q677H Pseudovirus Neutralization Assay kit _Luc reporter | |||
SC2087R | SARS-CoV-2 Y453F & Δ69-70 Pseudovirus Neutralization Assay kit _Luc reporter | |||
SC2087S | SARS-CoV-2 N501Y Pseudovirus Neutralization Assay kit _Luc reporter | |||
SC2087T | SARS-CoV-2 E484K & N501Y (B.1.1.7) Pseudovirus Neutralization Assay kit _Luc reporter | |||
SC2087U | SARS-CoV-2 L452R (B.1.617.1) Pseudovirus Neutralization Assay kit _Luc reporter | |||
SC2087V | SARS-CoV-2 L452R (B.1.617.2) Pseudovirus Neutralization Assay kit _Luc reporter | |||
SC2087W | SARS-CoV-2 L452R (B.1.617.2-CDC, Delta) Pseudovirus Neutralization Assay kit _Luc reporter | |||
SC2087X | SARS-CoV-2 L452R (AY.1, Delta plus) Pseudovirus Neutralization Assay kit _Luc reporter | |||
SC2087Y | SARS-CoV-2 L452Q (C.37, Lambda) Pseudovirus Neutralization Assay kit _Luc reporter | |||
SC2087Z | SARS-CoV-2 B.1.621 (Mu) Pseudovirus Neutralization Assay kit _Luc reporter | |||
SC2087-027 | SARS-CoV-2 B.1.1.529 (Omicron) Pseudovirus Neutralization Assay kit _Luc reporter | |||
GFP reporter kit | SC2087F | SARS-CoV-2 Pseudovirus Neutralization Assay kit _GFP reporter | ||
SC2087G | SARS-CoV-2 D614G Pseudovirus Neutralization Assay kit _ GFP reporter | |||
SC2087H | SARS-CoV-2 V367F Pseudovirus Neutralization Assay kit _ GFP reporter | |||
SC2087I | SARS-CoV-2 W436R Pseudovirus Neutralization Assay kit _ GFP reporter | |||
SC2087J | SARS-CoV-2 D364Y Pseudovirus Neutralization Assay kit _ GFP reporter |
* Components can be purchased separately. Please contact us.
Pseudovirus neutralization assay
Live virus neutralization assay
Figure 1. Comparable IC50 values of live virus and pseudovirus neutralization assay using the same sample.
Neutralization by ACE2-Fc
Figure 2. Positive control ACE2-Fc can effectively inhibit pseudovirus entry in a dose-dependent manner
Consistent IC50 in independent tests
Figure 3. Antibody candidates were screened for their ability to inhibit pseudovirus entry.
Neutralization by immunized mice serum
Figure 4. Immunized mouse serum can effectively inhibit pseudovirus entry
Figure 5. B.1.617.2 pseudovirus (Delta variant) was efficiently blocked by ACE2-Fc chimera proteins (left panel). RBD-63 mAb failed to inhibit the B.1.617.2 pseudovirus (Delta variant) infection (right panel).
Figure 6. Blocking Omicron pseudovirus entry into ACE2 overexpressing target cells by means of ACE2-Fc chimera protein.